DT06
MINIATURE
Needle type DIFFERENTIAL TEMPERATURE Sensor
The DT06 needle type differential temperature sensor is
used to perform continuous measurement of temperature differences as well as
absolute temperatures. It is meant for general monitoring of industrial
processes and in particular for detection of small thermal changes.

- Figure 1 DT06 is used for high
temperature applications up
to 450 degrees C.
- (1) sensor 1 (reference with
temperature)
- (3) metal sheathed connection cable
- (2) spring loaded bolt
(MF10x1)
- (4) metal sheathed cable
- (5) sensor 2
- (6) tefon extension cable
- Dimensions are in mm.
Free: For a nice clear print of the original product
brochure (PDF) click here.
INTRODUCTION
The DT06 has been designed for studies
of the energy balance of industrial installations, in particular to monitor
small changes within larger processes. In this application it can be useful to
monitor temperature differences between one location and the next rather than
absolute temperatures.
The main components are two matched
thermocouple sensors, incorporated in a fully stainless steel needles. These
sensors as well as their interconnecting wires can withstand temperatures up
to 450 degrees C.
The extension cable is made of Teflon.
Sensor output consists of a heat flux
signal (microvolt analog signal) and type K thermocouple. DT06 sensors can be
manufactured in such a way that they are fully exchangeable, which is easy for
servicing.
SUGGESTED USE
Studies
of energy balance of
industrial processes.
MORE INFORMATION / OPTIONS
- Alternative designs:
Hukseflux is specialised in heat flux
sensor design. For different applications special models can be constructed.
- Optional:
DT06 can be made in different diameters and
lengths. Extended temperature to 700 °C. (no spring)
Depending on the application,
amplifiers AC100 or NAM01 are used.
DT06 SPECIFICATIONS
-
Sensitivity (nominal): 40 10-6 V/K
-
Temperature range (total
sensor including metal sheathed cable): -55 to +450 °C
-
Temperature range
(Teflon cable): -55 to +260 °C
-
Heat flux output signal:
analog microvolts
-
Power requirements: No
power required
-
Optional: sensor length
and diameter, extended cable, cables with alternative colour codes, extended
temperature to 700 °C
-
Ordering code: DT06/L1/L2/L3/L4, L1 to L4 in
mm
-
Standard: DT06/30/1000/100/2500
-
Temperature sensor:
Thermocouple K, ANSI MC96.1-1982
-
Protection sensor tube: IP 68
-
Protection metal sheathed cable: IP 68
-
Protection Teflon cable: IP 67
|