TRSYS01 heat flux measuring system

TRSYS01 is a high-accuracy system for on-site measurement of thermal resistance
TRSYS01 for building physics studies
measuring thermal resistance, R, thermal conductance, the Λ-value, and thermal transmittance, the U-value, of building envelopes
TRSYS01's two measurement locations provide redundancy

High-accuracy heat flux measuring system with 2 measurement locations

TRSYS01 is a high-accuracy system for on-site measurement of thermal resistance, R, thermal conductance, the Λ-value, and thermal transmittance, the U-value, of building envelopes. TRSYS01 is mostly used for measurements according to standard practices of ISO 9869 and ASTM C1155 / C1046. The system is equipped with high-accuracy electronics, two heat flux sensors of model HFP01 as well as two pairs of matched thermocouples. The two measurement locations provide redundancy, leading to a high level of confidence in the measurement result. The high accuracy of the heat flux sensors and temperature difference measurements ensures that TRSYS01 continues measuring when other systems no longer perform; in particular at very low temperature differences across the wall.

Specifications

Measurand
  • heat flux (2 x)
  • temperature (2 x)
  • temperature difference (2 x)
A new version is available now!

This product is not available anymore. View the new version here:TRSYS20 thermal resistance measuring system

Specifications

Measurand
  • heat flux (2 x)
  • temperature (2 x)
  • temperature difference (2 x)
TRSYS01 specifications
  • :
Required data analysis to determine building R-value and U-value
  • to be performed by the user according to ISO and ASTM standard practices
Standards governing use of measuring system
  • ISO 9869 and ASTM C1155 / C1046
Number of measurement locations
  • 2 (can be increased on request)
Cable length per location
  • location 1: 10 m, location 2: 20 m
Rated operating temperature HFP01 and TC
  • -30 to +70 °C range
Uncertainty of calibration heat flux sensors
  • ± 3 % (k = 2)
Guard width to thickness ratio
  • 5 m/m (as required by ISO 9869 D.3.1)
Acceptance interval temperature difference measurement
  • ± 0.1 °C (required by ISO 9869, paragraph 5.2)
Measurement duration range
  • > 3 days
Data storage capacity
  • > 30 days
Adapter rated power supply
  • 110-220 VAC, 50 / 60 Hz
MCU specifications
  • :
Temperature difference measurement resolution
  • 0.02 °C
Heat flux measurement resolution
  • 0.02 W/m²
Connection to PC
  • via USB or RS232
Options
  • rechargeable battery pack for autonomous use
  • SR05-A1-TMBL pyranometer
  • more measurement locations

Description

TRSYS01 for building physics studies

Building physics

On-site measurements of thermal resistance, R, are often applied in studies of buildings. Alternatives are to measure its inverse value, the thermal conductance which is called the Λ-value, or the thermal transmittance which includes ambient air boundary layer thermal resistance, the U-value. The measurements of R are based on simultaneous time averaged measurement of heat flux Φ and differential temperature, ΔT, (using two temperature sensors on each on a different side of the wall).

R = ΔT / Φ

measuring thermal resistance, R, thermal conductance, the Λ-value, and thermal transmittance, the U-value, of building envelopes

Two or more measurement locations

The ISO and ASTM standards give detailed directions concerning the measurement method, sensor installation and data analysis. The TRSYS01 system employs dedicated sensors and electronics. Their high accuracy and sensitivity ensure that TRSYS01 will still measure under circumstances where competing systems no longer perform reliable measurements; i.e. down to very low heat fluxes and low temperature differences across the wall. The matched thermocouple pairs in TRSYS01, model TC, measure temperature differences with an uncertainty of better than 0.1 °C over the entire rated temperature range. TRSYS01 includes 2 x HFP01 heat flux plates. HFP01 is the world’s most popular sensor for heat flux measurement in studies of buildings.

 

TRSYS01's two measurement locations provide redundancy

Robust and stable

Equipped with heavy-duty components, TRSYS01 has proven to be very robust and stable. It survives repeated installation necessary in this application where measuring systems are typically used at multiple locations.

Suggested use

  • building U-value and R-value measurement
TRSYS01 heat flux measuring system
TRSYS01 is a high-accuracy system for on-site measurement of thermal resistance
  • temperature difference sensors: tested for 0.1 °C accuracy requirements
  • superior heat flux sensor, stable: waterproof (IP 67), corrosion-proof
  • continues measuring when others give up: high sensitivity amplifier + high sensitivity sensors
A new version is available now!

This product is not available anymore. View the new version here:TRSYS20 thermal resistance measuring system